Room-Based Air-cooled Air Conditioner
Shenglin Cooling is one of the toppest Room-Based Air-cooled Air Conditioner in China.During these years of exporting , Shenglin Cooling now has rich experience in the worldwide markets
  • information

CMA Room-Based Air-cooled Air Conditioner provides precision temperature and humidity control for large and medium-sized data rooms. It adopts a highly efficient compressor and EC centrifugal fan to meet the requirements of 24x7 all-weather continuous operation. It is the ideal choice for green and energy-saving data centers and various electronic equipment rooms.


CMA Room-Based Air-cooled Aircon

Indoor unit model

CMA3030

CMA3040

CMA3050

CMA4060

CMA4080

CMA4100

Main power supply

380V3Ph~50Hz

Air supply

Up/Down

Performance parameter

Cooling capacity(kW)

30.1

40.1

50.1

60.2

80.2

100.2

Sensible capacity(kW)

27.09

36.09

45.09

54.18

72.18

90.18

Max. operation current FLA(A)

46.5

55.5

55.5

86.1

106.4

106.4

Compressor OTY

1

1

1

2

2

2

Fan type

EC Centrifugal fan

Fan QYT

1

1

1

2

2

2

Circulating air volume(m³/h)

9200

11500

13500

18400

23000

27000

Heating capacity(kW)

6

9

9

9

15

15

Humidification(kg/h)

6

6

8

8

10

10

Connecting pipe size(30m)

Liquid pipe(mm)

16

22

22

16

22

22

Gas  pipe(mm

22

28

28

22

28

28

Humidification inlet pipe(Internal thread)

G1/2"

Drain pipe

Inner diameter 19mm, outer diameter 25mm, metal hose clamp connection

Unit Dimension and Weight

Dimension-W(mm)

780

1130

1130

1530

2230

2230

Dimension-D(mm)

996

Dimension-H(mm)

1975

Weight(kg)

285

460

460

690

880

880

Outdoor unit configuration(Outdoor Temp.45℃)

Flat-plate outdoor unit model

CMTO50SP

CMTO66SP

CMTO88SP

CMT050SP*2

CMT066SP*2

CMTO88SP*2

Centralized outdoor unit model

CMT050SF

CMT066SF

CMT088SF

CMT099SH

CMT132SH

CMT176SH

Electronic element specification

Air switch recommended(A)

63

63

63

100

125

125

Indoor power cable diameter

4*10.0+1*10.0

4*16.0+1*16.0

4*25.0+1*16.0

4*35.0+1*16.0

Note:
1. Standard working conditions: indoor ambient temperature 24℃, RH 50%, outdoor ambient temperature 35℃,ESP=100Pa;
2. Only cooling+electric heating or constant temperature and humidity type can beselected. The maximum working current and the recommended air switch are configure according to the constant temperature and humidity unit.
3. Optional water-cooled outdoor unit. For more information, please contact us.


CMA Room-Based Air-cooled Aircon(Fixed frequency)

Indoor unit model

CMA1025

CMA1030

CMA1040

CMA2060

CMA2070

CMA2080

CMA2090

CMA2100

Main power supply

380V3Ph~50Hz

Air supply

Up/Down

Performance parameter

Cooling capacity(kW)

25.5

30.5

40.8

61.3

70.5

81.7

90

100.8

Sensible capacity(kW)

23

27.5

36.7

55.2

63.5

73.5

81

90.7

Max. operation current FLA(A)

40.5

40.5

52.9

74.4

83

83

109.4

109.4

Compressor QTY

1

1

1

2

2

2

2

2

Fan type

EC Centrifugal fan

Fan QTY

1

1

1

2

2

2

2

2

Circulating air volume(m³/h)

7800

9200

11500

18400

21000

23000

25600

27000

Heating capacity(kW)

6

6

9

9

9

9

15

15

Humidification(kg/h)

5

5

8

8

8

8

10

10

Connecting pipe size(30m)

Liquid pipe(mm)

16

16

16

16

19

19

22

22

Gas pipe(mm)

22

22

25

22

25

25

28

28

Humidification inlet pipe(Interna l thread)

G1/2"

Drain pipe

Inner diameter 19mm, outer diameter 25mm, metal hose clamp connection

Unit dimension and weight

Dimension-W(mm)

780

780

930

1530

1830

1830

2230

2230

Dimension-D(mm)

996

Dimension-H(mm)

1975

Weight(kg)

285

285

350

690

810

810

880

880

Outdoor unit configuration(Outdoor Temp.40℃)

Flat-plate outdoor unit

CMTO44SP

CMTO44SP

CMT055SP

CMTO44SP*2

CMT055SP*2

CMT055SP*2

CMT077SP*2

CMT077SP*2

Outdoor unit configuration(Outdoor Temp.45℃)

Flat-plate outdoor unit

CMT050SP

CMTO50SP

CMT066SP

CMT050SP*2

CMT066SP*2

CMT066SP*2

MTO88SP*2

MTO88SP*2

Centralized outdoor unit

CMT050SF

CMT050SF

CMT066SF

CMTO99SH

CMT132SH

CMT132SH

CMT176SH

CMT176SH

Electronic element specification

Air switch recommended(A)

50

50

63

100

100

100

125

125

Indoor power cable diameter(mm²)

4*10.0+1*10.0

4*25.0+1*16.0

4*35.0+1*16.0

Note:
1. Standard working conditions: indoor ambient temperature 24℃, RH 50%, outdoor ambient temperature 35℃, ESP=100Pa;
2. Only cooling or constant temperature and humidity type can be selected. The maximum working current and the recommended air switch are configured according to the constant temperature and humidity unit.
3. Optional water-cooled outdoor unit. For more information, please contact us.


Application: data center, communication equipment and computer room, MRI and CT room, other precision equipment environment, such as precision processing, electronic instrument workshop, museum, archives, high-end wine cellar, medical equipment room, constant temperat

Reference
Country: Indonesia
Application:data center
Cooling capacity: 36.7kW
EER: 3.96
Air volume: 12750m3/h
Refrigerant: R410A
Power supply: 380V/3P/50Hz
Country: Philippines
Application: MRI room in hospital
Cooling capacity: 29.8kW
Electric heating: 11kW
Air volume: 7500m3/h
Refrigerant: R407C
Power supply: 400V/3P/60Hz
Downflow air supply
Country: USA
Application: Data center cooling
Cooling capacity: 18kW
Air volume: 4100m3/h
Refrigerant: R410A
Power supply: 400V/3P/60Hz
Remote control
Country: Tajikistan
Application: data base station
Cooling capacity: 13.1kW
Air volume: 2400m3/h
Refrigerant: R407C
Power supply: 380V/3P/50Hz
Country:China
Application: wind farm
Cooling capacity: 50kW
Air volume: 12000m3/h
Refrigerant: R22
Power supply: 380V/3P/50Hz
Product Catalog