Computer Room Air Conditioners Direct Expansion Unit
Shenglin Cooling is one of the toppest Computer Room Air Conditioners in China.During these years of exporting , Shenglin Cooling now has rich experience in the worldwide markets
  • information
CRAC DX unit utilizes the direct expansion cooling technology, where the refrigerant is compressed by a compressor into high-temperature and high-pressure gas. Then it expands through an expansion valve to become low-temperature and low-pressure gas, thereby achieving the desired cooling effect.

It uses efficient compressors and is equipped with EC centrifugal fans to meet the continuous operation requirements 24x7. It is an ideal choice for green and energy-efficient data centers and various electronic equipment rooms.


Introduction:
Computer Room Air Conditioners Direct Expansion Unit (CRAC DX unit) is an air conditioning equipment specifically designed for computer rooms. It utilizes direct expansion cooling technology, where the refrigerant is compressed by a compressor into high-temperature and high-pressure gas. Then it expands through an expansion valve to become low-temperature and low-pressure gas, thereby achieving the desired cooling effect.
It uses efficient compressors and is equipped with EC centrifugal fans to meet the continuous operation requirements 24x7. It is an ideal choice for green and energy-efficient data centers and various electronic equipment rooms.


Application:

Data centers
IDC computer rooms

Communication equipment and computer rooms

MRI and CT room constant temperature and humidity process environment

Constant temperature and humidity storage environment, and other precision instrument and equipment environments such as Precision Machining, Electronic instrument plants

Constant temperature and Humidity laboratories

Significant Features:

● Full inverter design: VSD compressors, EC fans, EXV
● V-shape condenser, saving 50%
● 7-inch touchscreen control, user-friendly interface
● Wet-film humidifier, 0-power consumption, no additional heat
● Optional electrode humidifier for precision humidity control


Features:

High-performance components achieve comprehensive and efficient cooling from parts to systems;

Variable air volume without snail shell backward EC centrifugal fan with infinitely variable frequency regulation;

High-precision electronic expansion valve automatically adjusts refrigerant flow according to demand;

Internally threaded copper tube + efficient low-pressure loss finned tube, large heat exchange area;

Efficient electrode/wet film humidification with fast humidification speed and low power consumption;

Unique condensation pressure precise control system to enhance system safety;

Modular design supports full front maintenance;

Power-off memory, auto-start on power-on, group control networking, flexible configuration, maximum group control quantity up to 32 units;

Optional modules for power measurement, dual power supply, and lightning protection device.


Technical Data:

CMA Room-Based Air-cooled Aircon

Indoor unit model

CMA3030

CMA3040

CMA3050

CMA4060

CMA4080

CMA4100

Main power supply

380V3Ph~50Hz

Air supply

Up/Down

Performance parameter

Cooling capacity(kW)

30.1

40.1

50.1

60.2

80.2

100.2

Sensible capacity(kW)

27.09

36.09

45.09

54.18

72.18

90.18

Max. operation current FLA(A)

46.5

55.5

55.5

86.1

106.4

106.4

Compressor OTY

1

1

1

2

2

2

Fan type

EC Centrifugal fan

Fan QYT

1

1

1

2

2

2

Circulating air volume(m³/h)

9200

11500

13500

18400

23000

27000

Heating capacity(kW)

6

9

9

9

15

15

Humidification(kg/h)

6

6

8

8

10

10

Connecting pipe size(30m)

Liquid pipe(mm)

16

22

22

16

22

22

Gas  pipe(mm

22

28

28

22

28

28

Humidification inlet pipe(Internal thread)

G1/2"

Drain pipe

Inner diameter 19mm, outer diameter 25mm, metal hose clamp connection

Unit Dimension and Weight

Dimension-W(mm)

780

1130

1130

1530

2230

2230

Dimension-D(mm)

996

Dimension-H(mm)

1975

Weight(kg)

285

460

460

690

880

880

Outdoor unit configuration(Outdoor Temp.45℃)

Flat-plate outdoor unit model

CMTO50SP

CMTO66SP

CMTO88SP

CMT050SP*2

CMT066SP*2

CMTO88SP*2

Centralized outdoor unit model

CMT050SF

CMT066SF

CMT088SF

CMT099SH

CMT132SH

CMT176SH

Electronic element specification

Air switch recommended(A)

63

63

63

100

125

125

Indoor power cable diameter

4*10.0+1*10.0

4*16.0+1*16.0

4*25.0+1*16.0

4*35.0+1*16.0

Note:
1. Standard working conditions: indoor ambient temperature 24℃, RH 50%, outdoor ambient temperature 35℃,ESP=100Pa;
2. Only cooling+electric heating or constant temperature and humidity type can beselected. The maximum working current and the recommended air switch are configure according to the constant temperature and humidity unit.
3. Optional water-cooled outdoor unit.



CMA Room-Based Air-cooled Aircon(Fixed frequency)

Indoor unit model

CMA1025

CMA1030

CMA1040

CMA2060

CMA2070

CMA2080

CMA2090

CMA2100

Main power supply

380V3Ph~50Hz

Air supply

Up/Down

Performance parameter

Cooling capacity(kW)

25.5

30.5

40.8

61.3

70.5

81.7

90

100.8

Sensible capacity(kW)

23

27.5

36.7

55.2

63.5

73.5

81

90.7

Max. operation current FLA(A)

40.5

40.5

52.9

74.4

83

83

109.4

109.4

Compressor QTY

1

1

1

2

2

2

2

2

Fan type

EC Centrifugal fan

Fan QTY

1

1

1

2

2

2

2

2

Circulating air volume(m³/h)

7800

9200

11500

18400

21000

23000

25600

27000

Heating capacity(kW)

6

6

9

9

9

9

15

15

Humidification(kg/h)

5

5

8

8

8

8

10

10

Connecting pipe size(30m)

Liquid pipe(mm)

16

16

16

16

19

19

22

22

Gas pipe(mm)

22

22

25

22

25

25

28

28

Humidification inlet pipe(Interna l thread)

G1/2"

Drain pipe

Inner diameter 19mm, outer diameter 25mm, metal hose clamp connection

Unit dimension and weight

Dimension-W(mm)

780

780

930

1530

1830

1830

2230

2230

Dimension-D(mm)

996

Dimension-H(mm)

1975

Weight(kg)

285

285

350

690

810

810

880

880

Outdoor unit configuration(Outdoor Temp.40℃)

Flat-plate outdoor unit

CMTO44SP

CMTO44SP

CMT055SP

CMTO44SP*2

CMT055SP*2

CMT055SP*2

CMT077SP*2

CMT077SP*2

Outdoor unit configuration(Outdoor Temp.45℃)

Flat-plate outdoor unit

CMT050SP

CMTO50SP

CMT066SP

CMT050SP*2

CMT066SP*2

CMT066SP*2

MTO88SP*2

MTO88SP*2

Centralized outdoor unit

CMT050SF

CMT050SF

CMT066SF

CMTO99SH

CMT132SH

CMT132SH

CMT176SH

CMT176SH

Electronic element specification

Air switch recommended(A)

50

50

63

100

100

100

125

125

Indoor power cable diameter(mm²)

4*10.0+1*10.0

4*25.0+1*16.0

4*35.0+1*16.0

Note:
1.Standard working conditions: indoor ambient temperature 24℃, RH 50%, outdoor ambient temperature 35℃, ESP=100Pa;
2. Only cooling or constant temperature and humidity types can be selected. The maximum working current and the recommended air switch are configured according to the constant
3. temperature and humidity unit. Optional water-cooled outdoor unit.


Product Catalog