- Tel: 0086-21-35324116
- E-mail: sales@shenglincooling.com
Features
Adiabatic dry cooler are air-cooled coolers with adiabatic pre-coolers. Before the fan draws the ambient air through the coil, the air is pre-cooled adiabatically when traversing an humidification pad. This evaporates the water in the air, thus boosting the cooling capacity.
References
Country: USA
Application: Bitcoin immersion cooling system
Cooling capacity: 1270kW
Cooling medium: BC-888
Supply power: 415V/3P/60Hz
Fan brand: Ziehl-Abegg
Country: USA
Application: Bitcoin immersion cooling system
Cooling capacity: 171kW
Cooling medium: water
Supply power: 415V/3P/60Hz
Fan brand: Chinese brand
Technical Data
Air discharge direction |
|
Performance ranges |
Cooling capacity: from 176 to 792 kw Air volume: from 21454 to 227449 m3/h Sound pressure level: from 54 to 66 dB A(10m) Dry coolers:customized on demand |
High efficiency heat exchanger |
Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany |
Fan |
Only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw. Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Voltage:400V/3N/50Hz Air separator for each fan. |
Testing |
Heat exchangers are supplied clean and tested at a pressure of 30 bars |
Options |
Coil design refrigerant: water, oil, glycol. Multiple circuits. Sub-cooling circuits. Stainless steel or aluminum casing. Coated aluminum or copper fins. Explosion ploof motor. Customized fin spacing.
|
Technical Data
Dry cooler SHSL-D4 series parameter(fin space 2.1mm)
|
SHSL-D4-176-4X800 |
SHSL-D4-191-4X800 |
SHSL-D4-205-4X800 |
SHSL-D4-267-6X800 |
SHSL-D4-291-6X800 |
SHSL-D4-315-6X800 |
SHSL-D4-361-8X800 |
SHSL-D4-394-8X800 |
SHSL-D4-414-8X800 |
||||||
Capacity |
Water |
35℃ outdoor temp. |
Inlet |
45℃, |
KW |
175.6 |
190.6 |
205.4 |
266.5 |
291.2 |
314.6 |
361.4 |
394.4 |
414.4 |
|
outlet |
40℃ |
||||||||||||||
20% Glycol |
Inlet |
45℃ |
171.5 |
186.5 |
201.0 |
258.0 |
282.3 |
308.6 |
352.9 |
385.6 |
405.6 |
||||
outlet |
40℃ |
||||||||||||||
Medium |
Water flow |
M3/h |
30.5 |
33.1 |
35.7 |
46.3 |
50.6 |
54.7 |
62.8 |
68.6 |
72.1 |
||||
Pressure drop |
kPa |
98 |
84 |
70 |
48 |
39 |
93 |
98 |
82 |
65 |
|||||
Air flow |
M3/h |
86771 |
83195 |
79955 |
13054 |
124786 |
119924 |
173533 |
166376 |
159905 |
|||||
Fan motor(400V/3N/50HZ) |
W |
7200 |
7200 |
7200 |
10800 |
10800 |
10800 |
1440 |
1440 |
1440 |
|||||
A |
15.2 |
15.2 |
15.2 |
22.8 |
22.8 |
22.8 |
30.4 |
30.4 |
30.4 |
||||||
Fan |
No X φ |
2X2X800 |
2X2X800 |
2X2X800 |
2X3X800 |
2X3X800 |
2X3X800 |
2X4X800 |
2X4X800 |
2X4X800 |
|||||
Sound pressure level |
dB(A) |
54.0 |
54.0 |
54.0 |
56.0 |
56.0 |
56.0 |
58.0 |
58.0 |
58.0 |
|||||
10m |
|||||||||||||||
Dimension |
L |
mm |
2670 |
2670 |
2670 |
3870 |
3870 |
3870 |
5070 |
5070 |
5070 |
||||
W |
mm |
2250 |
2250 |
2250 |
2250 |
2250 |
2250 |
2250 |
2250 |
2250 |
|||||
H |
mm |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
|||||
Inlet φ |
mm |
2X2-1/2” |
2X2-1/2” |
2X2-1/2” |
2X3” |
2X3” |
2X3” |
2X4” |
2X4” |
2X4” |
|||||
Inlet φ |
mm |
2X2-1/2” |
2X2-1/2” |
2X2-1/2” |
2X3” |
2X3” |
2X3” |
2X4” |
2X4” |
2X4” |
|||||
Product weight(empty) |
kg |
698 |
735 |
835 |
1135 |
1225 |
1617 |
1753 |
1894 |
2042 |
Type |
SHSL-D4-428-10X800 |
SHSL-D4-488-10X800 |
SHSL-D4-510-10X800 |
SHSL-D4-520-12X800 |
SHSL-D4-591-12X800 |
SHSL-D4-617-12X800 |
SHSL-D4-724-14X800 |
SHSL-D4-792-16X800 |
||||||
Capacity |
Water |
35℃ outdoor temp. |
Inlet |
45℃, |
KW |
427.6 |
488.1 |
509.9 |
519.9 |
590.7 |
616.7 |
723.6 |
791.6 |
|
outlet |
40℃ |
|||||||||||||
20% Glycol |
Inlet |
45℃ |
411.0 |
476.6 |
498.6 |
503.5 |
579.2 |
605.5 |
712.4 |
777.2 |
||||
outlet |
40℃ |
|||||||||||||
Medium |
Water flow |
M3/h |
74.3 |
84.9 |
88.7 |
90.4 |
102.7 |
107.2 |
125.8 |
137.6 |
||||
Pressure drop |
kPa |
28 |
60 |
48 |
43 |
99 |
78 |
99 |
99 |
|||||
Air flow |
M3/h |
216938 |
202183 |
193538 |
260320 |
242613 |
232238 |
270940 |
323168 |
|||||
Fan motor(400V/3N/50HZ) |
W |
18000 |
18000 |
18000 |
21600 |
21600 |
21600 |
25200 |
28800 |
|||||
A |
38.00 |
38.00 |
38.00 |
45.60 |
45.60 |
45.60 |
53.20 |
60.80 |
||||||
Fan |
No X φ |
2X5X800 |
2X5X800 |
2X5X800 |
2X6X800 |
2X6X800 |
2X6X800 |
2X7X800 |
2X8X800 |
|||||
Sound pressure level |
dB(A) |
60.0 |
60.0 |
60.0 |
62.0 |
62.0 |
62.0 |
64.0 |
66.0 |
|||||
10m |
||||||||||||||
Dimension |
L |
mm |
6270 |
6270 |
6270 |
7470 |
7470 |
7470 |
8670 |
9870 |
||||
W |
mm |
2520 |
2520 |
2520 |
2520 |
2520 |
2520 |
2520 |
2520 |
|||||
H |
mm |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
|||||
Inlet φ |
mm |
2X4” |
2XDN125 |
2XDN125 |
2XDN125 |
2XDN125 |
2XDN125 |
2XDN125 |
2XDN125 |
|||||
Inlet φ |
mm |
2X4” |
2XDN125 |
2XDN125 |
2XDN125 |
2XDN125 |
2XDN125 |
2XDN125 |
2XDN125 |
|||||
Product weight(empty) |
kg |
2159 |
2250 |
2327 |
2480 |
2568 |
2741 |
2947 |
3342 |
Application
Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, smelting, etc..
Suitable for all equipment which needs heat dissipation and is installed in the open air.
Best Suited for Telecom/Data Center/Colocation/Hosting